slides

Characterization of secondary ignition sources in unattended compartments and full-scale baseline test

Abstract

The characteristics of five fuel loads burned within a metal lavatory were identified. In 15 of the tests the lavatory door remained closed for the 30-minute test period while in 15 additional tests the door was opened after the fire had developed. Upon completion of these tests the most severe source was selected for use in the baseline test. In the baseline test, the lavatory and adjacent panels, all of which were constructed of contemporary materials, were tested for a period of 1 hour. Thermal, environmental, and biological data were obtained for all fuel loads, door conditions, and the baseline test. All tests were conducted in a cabin fire simulator with separate ventilation of the cabin and lavatory representative of an inflight condition. The baseline test established that by using the most severe fuel source: (1) the exposed animal subject survived without complications; (2) no toxic levels of gas within the cabin were detected; (3) a propagating fire did not develop in adjacent structures; (4) the lavatory containing the fire remained structurally intact; (5) decomposition of portions of the lavatory did occur; and (6) cabin visibility would have presented a problem after 5 minutes

    Similar works