research

An unconventional approach to imaging radar calibration

Abstract

An unconventional approach to imaging radar calibration was considered for the entire system, including the imaging processing as a measurement instrument. The technique made use of a calibrated aircraft scatterometer as a secondary standard to measure the backscatter (sigma zero) of large units of constant roughness. These measured roughness units when viewed by an imaging radar system can be used to provide gray scale level, corresponding to known degrees of roughness. To obtain a calibrated aircraft scatterometer, a homogeneous smooth surface was measured by both the aircraft scatterometer and a sphere calibrated ground system. This provided a measure of the precision and accuracy of the aircraft system. The aircraft system was then used to measure large roughness units in the Death Valley, California area. Transfer of the measured roughness units to radar imagery was demonstrated