research
Investigation of Effectiveness of Air-Heating a Hollow Steel Propeller for Protection Against Icing. 3: 25% Partitioned Blades
- Publication date
- Publisher
Abstract
The icing protection obtained from an internally air-heated propeller blade partitioned to confine the heated air forward of 25-percent chord was investigated in the NACA Cleveland icing research tunnel. A production-model hollow steel propeller was modified with an Internal radial partition at 25-percent chord and with shank and tip openings to admit and exhaust the heated air. Temperatures were measured on the blade surfaces and in the heated-air system during tunnel icing conditions. Heat-exchanger effectiveness and photographs of Ice formations on the blades were obtained. Surface temperature measurements indicated that confining the heated air forward of the 25-percent chord gave.a more economical distribution of the applied heat as compared with unpartitioned and 50-percent partitioned blades, by dissipating a greater percentage of the available heat at the leading edge. At a propeller speed of 850 rpm, a heating rate of 7000 Btu per hour per blade at a shank air temperature of 400 F provided adequate Icing protection at ambient-air temperatures of 23 F but not at temperatures as low as 15 F. With the heating rate used, a heat-exchanger effectiveness of 77 percent was obtained as compared to 56 percent for 50-percent partitioned and 47 percent for unpartitioned blades