research

Thermal protection of reentry vehicles by actively cooled nosetips

Abstract

Analytical modeling efforts and clear-air ground test results of a transportation-cooled nosetips (TCNT) design are presented. The discrete water injection platelet TCNT described was conceived and created to achieve the performance requirements for severe reentry vehicle trajectories. Thermal performance computer modeling techniques, combing both local heat blockage and boundary layer recovery enthalpy reduction are outlined

    Similar works