research

Experimental and analytical results of tangential blowing applied to a subsonic V/STOL inlet

Abstract

Engine inlets for subsonic V/STOL aircraft must operate over a wide range of conditions without internal flow separation. Experimental and analytical investigations were conducted to evaluate the effectiveness of tangential blowing to maintain attached flow to high angles of attack. The inlet had a relatively thin lip with a blowing slot located either on the lip or in the diffuser. The height and width of these slots was varied. Experimentally determined flow separation boundaries showed that lip blowing achieved higher angle of attack capability than diffuser blowing. This capability was achieved with the largest slot circumferential extent and either of the two slot heights. Predicted (analytical) separation boundaries showed good agreement except at the highest angles of attack

    Similar works