High Rate Discharge Studies of LI/SO2 Batteries
- Publication date
- Publisher
Abstract
A battery composed of twelve lithium/sulfur dioxide D size cells in series is forced discharged at 21 amperes. This current is established by the proposed use of the battery and represented a discharge condition which might produce venting. Discharge of the battery into voltage reversal results not only in cells venting but also in the violent rupture of at least one cell