An investigation to determine the most likely cause of two failures of five tests on 79 inch diameter Lockheed Super*Zip spacecraft separation joints being used for the development of a Shuttle/Centaur propulsion system. This joint utilizes an explosively expanded tube to fracture surrounding prenotched aluminum plates to achieve planar separation. A test method was developed and more than 300 tests firings were made to provide an understanding of severance mechanisms and the functional performance effects of system variables. An approach for defining functional margin was developed, and specific recommendations were made for improving existing and future systems