Hydrogen oxidation mechanism with applications to (1) the chaperon efficiency of carbon dioxide and (2) vitiated air testing

Abstract

Ignition delay times for the hydrogen/oxygen/carbon dioxide/argon system were obtained behind reflected shock waves. A detailed kinetic mechanism modeled the experimental hydrogen/oxygen data, Skinner and Ringrose's high-pressure data, and Slack and Grillo's hydrogen/air data. A carbon dioxide chaperon efficiency of 7.0 +/- 0.2 was determined. The reaction pathway H2O yields H2O2 yields OH yields H was required to model the high-pressure data. It is suggested that some of the lowest temperature data points (1.0 and 0.5 atm) for Slack and Grillo's hydrogen/air experiments are in error. It was found that the technique of simplifying a detailed kinetic mechanism for a limited range of experimental data may render the model useless for other test conditions

    Similar works