research

Arcing and discharges in high-voltage subsystems of Space Station

Abstract

Arcing and other types of electrical discharges are likely to occur in high-voltage subsystems of the Space Station. Results from ground and space experiments on the arcing of solar cell arrays are briefly reviewed, showing that the arcing occurs when the conducting interconnects in the arrays are at negative potential above a threshold, which decreases with the increasing plasma density. Furthermore, above the threshold voltages the arcing rate increases with the plasma density. At the expected operating voltages (approximately 200 V) in the solar array for the space station, arcing is expected to occur even in the ambient ionospheric plasma. If the ionization of the contaminants increases the plasma density near the high-voltage systems, the adverse effects of arcing on the solar arrays and the space station are likely to be enhanced, In addition to arcing other discharge processes are likely to occur in high-voltage subsystems. For example, Paschen discharge is likely to occur when the neutral density N sub n greater that 10 to the 12th cu cm, the corresponding neutral pressure P greater than 3 x 10 to the -5 Torr