research

Calibration of the visible and near-infrared channels of the LANDSAT-5 Thematic Mapper using high-altitude aircraft measurements

Abstract

Visible near-infrared sensors mounted on operational satellites now in use do not have on-board full aperture absolute calibration devices. One means of establishing an in-orbit calibration for a satellite sensor is to make simultaneous measurements of a bright, uniform scene along the satellite view vector from a calibrated instrument on board a high altitude aircraft. In the work reported here, aircraft data were recorded over White Sands, New Mexico at satellite overpass time for the LANDSAT-5 Thematic Mapper (TM). A comparison of the coincident aircraft and orbiting satellite data showed the radiometric gain for TM channel 1 had degraded 4.7 percent by August 28, 1985; gains for TM channels 2 and 3 were within 1 percent of prelaunch values

    Similar works