research

Emergency egress requirements for Space Station Freedom

Abstract

An objective was to determine if the pressurized elements and hatchways of the Space Station Freedom support the emergency egress of crewmembers during operation of the station at the stage of Permanently Manned Capacity. Emergency egress was defined as the exit from a pressurized element when an event occurs which makes that element uninhabitable. The possible egress paths for four emergency scenarios considered were: (1) accident occurs in a module and crewmembers translate to the attached node; (2) accident occurs at a node and crewmembers translate through it to the safe node; (3) accident occurs at a module close to a node and crewmembers are not able to translate through the affected area; and (4) accident occurs at a node and crewmembers cannot translate through it. The structural design of the pressurized elements and the hatches studied is adequate for the emergence egress translation requirement. The current location of a few racks may cause some obstruction for egress to the orbiter. The egress time required in the worst situation is estimated to be about 3 mins. There is a chance of getting crewmembers trapped in a module in case of a severe accident. Aids are needed for emergency egress translation

    Similar works