research
Electrical and infrared properties of thin niobium microbolometers near T(sub c)
- Publication date
- Publisher
Abstract
Niobium microbolometers approximately 1 micron wide x 2 micron long x 10 nm thick have been integrated at the feeds of equiangular spiral antennas made of 200 nm thick Nb. The device's current-voltage characteristics and infrared responsivity as a function of DC bias voltage were measured over a range of temperature spanning approximately plus or minus 2 percent around T(sub c). The greatest voltage responsivity occurs well below T(sub c), in a regime where the I-V curve is significantly hysteretic due to self-heating and resembles the I-V curve of a superconducting microbridge