Analytical Investigation of a Reflux Boiler

Abstract

A thermal model of a single Ultralight Fabric Reflux Tube (UFRT) was constructed and tested against data for an array of such tubes tested in the NASA-JSC facility. Modifications to the single fin model were necessary to accommodate the change in radiation shape factors due to adjacent tubes. There was good agreement between the test data and data generated for the same cases by the thermal model. The thermal model was also used to generate single and linear array data for the lunar environment (the primary difference between the test and lunar data was due to lunar gravity). The model was also used to optimize the linear spacing of the reflux tubes in an array. The optimal spacing of the tubes was recommended to be about 5 tube diameters based on maximizing the heat transfer per unit mass. The model also showed that the thermal conductivity of the Nextel fabric was the major limitation to the heat transfer. This led to a suggestion that the feasibility of jacketing the Nextel fiber bundles with copper strands be investigated. This jacketing arrangement was estimated to be able to double the thermal conductivity of the fabric at a volume concentration of about 12-14%. Doubling the thermal conductivity of the fabric would double the amount of heat transferred at the same steam saturation temperature

    Similar works