Experimental and Computational Studies of the Flow Over a Sting Mounted Planetary Probe Configuration
- Publication date
- Publisher
Abstract
This paper summarizes the results of a series of experimental studies in the LENS shock tunnel and computations with DSMC and Navier Stokes codes which have been made to examine the aerothermal and flowfield characteristics of the flow over a sting-supported planetary probe configuration in hypervelocity air and nitrogen flows. The experimental program was conducted in the LENS hypervelocity shock tunnel at total enthalpies of 5and 10 MJkg for a range of reservoir pressure conditions from 70 to 500 bars. Heat transfer and pressure measurements were made on the front and rear face of the probe and along the supporting sting. High-speed and single shot schlieren photography were also employed to examine the flow over the model and the time to establish the flow in the base recirculation region. Predictions of the flowfield characteristics and the distributions of heat transfer and pressure were made with DSMC codes for rarefied flow conditions and with the Navier-Stokes solvers for the higher pressure conditions where the flows were assumed to be laminar. Analysis of the time history records from the heat transfer and pressure instrumentation on the face of the probe and in the base region indicated that the base flow was fully established in under 4 milliseconds from flow initiation or between 35 and 50 flow lengths based on base height. The measurements made in three different tunnel entries with two models of identical geometries but with different instrumentation packages, one prepared by NASA Langley and the second prepared by CUBRC, demonstrated good agreement between heat transfer measurements made with two different types of thin film and coaxial gage instrumentation. The measurements of heat transfer and pressure to the front face of the probe were in good agreement with theoretical predictions from both the DSMC and Navier Stokes codes. For the measurements made in low density flows, computations with the DSMC code were found to compare well with the pressure and heat transfer measurements on the sting, although the computed heat transfer rates in the recirculation region did not exhibit the same characteristics as the measurements. For the 10MJkg and 500 bar reservoir match point condition, the measurements and heat transfer along the sting from the first group of studies were in agreement with the Navier Stokes solutions for laminar conditions. A similar set of measurements made in later tests where the model was moved to a slightly different position in the test section indicated that the boundary layer in the reattachment compression region was close to transition or transitional where small changes in the test environment can result in larger than laminar heating rates. The maximum heating coefficients on the sting observed in the present studies was a small fraction of similar measurements obtained at nominally the same conditions in the HEG shock tunnel, where it is possible for transition to occur in the base flow, and in the low enthalpy studies conducted in the NASA Langley high Reynolds number Mach 10 tunnel where the base flow was shown to be turbulent. While the hybrid Navier- StokedDMSC calculations by Gochberg et al. (Reference 1) suggested that employing the Navier- Stokes calculations for the entire flowfield could be seriously in error in the base region for the 10 MJkg, 500 bar test case, similar calculations performed by Cornell, presented here, do not