The design, construction and test of a charged particle detector made of
scintillation counters read by Silicon Photomultipliers (SiPM) is described.
The detector, which operates in vacuum and is used as a veto counter in the
NA62 experiment at CERN, has a single channel time resolution of 1.14 ns, a
spatial resolution of ~2.5 mm and an efficiency very close to 1 for penetrating
charged particles