research
Newborn screening using tandem mass spectrometry: A systematic review
- Publication date
- Publisher
Abstract
Objectives: To evaluate the evidence for the clinical effectiveness of neonatal screening for phenylketonuria (PKU) and medium-chain acyl-coA dehydrogenase (MCAD) deficiency using tandem mass spectrometry (tandem MS).
Study design: Systematic review of published research.
Data sources: Studies were identified by searching 12 electronic bibliographic databases; conference proceedings and experts consulted.
Results: Six studies were selected for inclusion in the review. The evidence of neonatal screening for PKU and MCAD deficiency using tandem MS was primarily from observational data of large-scale prospective newborn screening programmes and systematic screening studies from Australia, Germany and the USA. Tandem MS based newborn screening of dried blood spots for PKU and/or MCAD deficiency was shown to be highly sensitive (>93.220%) and highly specific (>99.971%). The false positive rate for PKU screening was less than 0.046% and for MCAD deficiency the false positive rate was less than 0.023%. The positive predictive values ranged from 20 to 32% and 19 to 100%, respectively.