research

Vacuum sieve tray for tritium extraction from liquid Pb–17Li

Abstract

Formation of droplet of liquid Li–17Pb released from a nozzle into vacuum was studied for the evaluation of the feasibility as a tritium extraction process. Size of droplets formed from the nozzles was estimated by theoretical and experimental methods. For the theoretical estimation, the non-dimensional comparison of the physical bulk property of liquid Pb–17Li with water (H2O) at ambient temperature was applied. It was found to be reasonable to apply the Plateau-Rayleigh-Instability theory for the droplet size formula of the fluid Pb–17Li for the nozzle diameter 0.4 mm–1.0 mm, temperature 400 °C–500 °C, at initial velocity of 3 m/s. The experimental results of the droplet size showed good agreement with the theory. This device was used for the parametric study of extraction of deuterium during their free fall in vacuum. The scaling of the device suggests the engineering feasibility of the process

    Similar works