Effects of thermal conduction in sonoluminescence

Abstract

We show by numerical hydrodynamic calculations that there are two important effects of thermal conduction in sonoluminescence: (i) the bubble remains close to being isothermal during the expansion phase; and (ii) a cold, dense layer of air is formed at the bubble wall during the contraction phase. These conclusions are not sensitive to the particular equation of state used, although details of the dynamical evolution of the bubble are