A long-term in vitro silicon-based microelectrode-neuron connection

Abstract

A novel method for long-term recording and simulation applicable to cultured neurons has been developed. Silicon-based microelectrodes have been fabricated using integrated-circuit technology and micromachining. The chronic connection is made by positioning the tip of the `diving-board electrode' into contact with the top of the cell body. The electrode support structure is then glued to the bottom of the culture dish. Two-way electrical connections to Helisoma B19 neurons have been maintained for up to four days. This capability makes it possible to conduct experiments that are not practical using conventional techniques