Residual Bias Phenomenon in Air‐Coupled Ultrasonic Capacitive Film Transducers

Abstract

We discuss in this paper the underlying physics of a residual bias phenomenon, whereby the metalized Mylar films of air‐coupled film transducers accept and retain a residual electrostatic charge. Experimental measurements to demonstrate and quantify this effect are reported here, along with a hypothesis of the mechanism of charge transfer and embedding. The measurements show the amplitude performance of the capacitive film transducers as a function of applied bias voltage and frequency. Factors such as humidity and decay time also play roles in the acquisition and holding of charge on a film. We hypothesize that charge transfers from the conductive backplate and collects on the non‐metalized side of the film. The charged films therefore are electrostatically attracted to the transducer backplate even with no applied voltage bias. Typically, an externally applied bias voltage is needed to charge the capacitor. With a persistent residual bias effect, these air‐coupled capacitive film transducers could be used like conventional piezoelectric transducers with no biasing required. This effect has substantial implications for the operation of air‐coupled film transducers

    Similar works