Abstract

The results and conclusions of a prevalidation study on alternative methods for skin corrosivity testing are described in this workshop report. The three methods assessed were: the transcutaneous electrical resistance assay with excised rat skin; CORROSITEX; and Skin2. QSAR data skin corrosivity are presented in an appendix.JRC.(EI)-Environment Institut