A Breakdown Voltage Extraction Technique Using Numerical Modeling In Mos Structures

Abstract

In this paper, the potential profile that is based on the numerical solution of the Poisson's equation can be used to determine the breakdown voltage of any MOS structures. To validate this work, a comparison between an experimental breakdown voltage and a calculated one. One of the important applications of this method is to make optimum designs to meet predetermined breakdown voltages