To access publisher full text version of this article. Please click on the hyperlink in Additional Links fieldPublished guidelines recommend spirometry to accurately diagnose chronic obstructive pulmonary disease (COPD). However, even spirometry-based COPD prevalence estimates can vary widely. We compared properties of several spirometry-based COPD definitions using data from the international Burden of Obstructive Lung Disease (BOLD)study. 14 sites recruited population-based samples of adults aged > or =40 yrs. Procedures included standardised questionnaires and post-bronchodilator spirometry. 10,001 individuals provided usable data. Use of the lower limit of normal (LLN) forced expiratory volume in 1 s (FEV(1)) to forced vital capacity (FVC) ratio reduced the age-related increases in COPD prevalence that are seen among healthy never-smokers when using the fixed ratio criterion (FEV(1)/FVC <0.7) recommended by the Global Initiative for Chronic Obstructive Lung Disease. The added requirement of an FEV(1) either <80% predicted or below the LLN further reduced age-related increases and also led to the least site-to-site variability in prevalence estimates after adjusting for potential confounders. Use of the FEV(1)/FEV(6) ratio in place of the FEV(1)/FVC yielded similar prevalence estimates. Use of the FEV(1)/FV