Adaptive High-Bandwidth Digitally Controlled Buck Converter with Improved Line and Load Transient Response

Abstract

Digitally controlled switching converter suffers from bandwidth limitation because of the additional phase delay in the digital feedback control loop. In order to overcome the bandwidth limitation without using a high sampling rate, this paper presents an adaptive third-order digital controller for regulating a voltage-mode buck converter with a modest 2x oversampling ratio. The phase lag due to the ADC conversion time delay is virtually compensated by providing an early estimation of the error voltage for the next sampling time instant, enabling a higher unity-gain bandwidth without compromising stability. An additional pair of low-frequency pole and zero in the third-order controller increases the low-frequency gain, resulting in faster settling time and smaller output voltage deviation during line transient. Both simulation and experimental results demonstrate that the proposed adaptive third-order controller reduces the settling time by 50% in response to a 1 V line transient and 30% in response to a 600 mA load transient, compared to the baseline static second-order controller. The fastest settling time is measured to be around 11.70 s, surpassing the transient performance of conventional digital controllers and approaching that of the state-of-the-art analog-based controllers.postprin