CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
research
Assessing 3D tunnel position in ACL reconstruction using a novel single image 3D-2D registration
Authors
PYS Cheung
Y Hu
+4 more
X Kang
Y Otake
RH Taylor
WP Yau
Publication date
1 January 2012
Publisher
'SPIE-Intl Soc Optical Eng'
Doi
Cite
Abstract
Poster Session: 2D/3D and FluoroscopyConference Theme: Image-Guided Procedures, Robotic Interventions, and ModelingThe routinely used procedure for evaluating tunnel positions following anterior cruciate ligament (ACL) reconstructions based on standard X-ray images is known to pose difficulties in terms of obtaining accurate measures, especially in providing three-dimensional tunnel positions. This is largely due to the variability in individual knee joint pose relative to X-ray plates. Accurate results were reported using postoperative CT. However, its extensive usage in clinical routine is hampered by its major requirement of having CT scans of individual patients, which is not available for most ACL reconstructions. These difficulties are addressed through the proposed method, which aligns a knee model to X-ray images using our novel single-image 3D-2D registration method and then estimates the 3D tunnel position. In the proposed method, the alignment is achieved by using a novel contour-based 3D-2D registration method wherein image contours are treated as a set of oriented points. However, instead of using some form of orientation weighting function and multiplying it with a distance function, we formulate the 3D-2D registration as a probability density estimation using a mixture of von Mises-Fisher- Gaussian (vMFG) distributions and solve it through an expectation maximization (EM) algorithm. Compared with the ground-truth established from postoperative CT, our registration method in an experiment using a plastic phantom showed accurate results with errors of (-0.43°±1.19°, 0.45°±2.17°, 0.23°±1.05°) and (0.03±0.55, -0.03±0.54, -2.73±1.64) mm. As for the entry point of the ACL tunnel, one of the key measurements, it was obtained with high accuracy of 0.53±0.30 mm distance errors. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).published_or_final_versionSPIE Medical Imaging 2012, San Diego, CA., 4-9 February 2012. In Progress in Biomedical Optics and Imaging, 2012, v. 8316, art. no. 83162
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
HKU Scholars Hub
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:hub.hku.hk:10722/158786
Last time updated on 01/06/2016