doi: 10.1109/IEMBS.2004.1403269Hyperglycaemia in critically ill patients increases the
risk of further complications and mortality. A long-term
verification of a model that captures the essential glucose- and
insulin-kinetics is presented, using retrospective data gathered
in an Intensive Care Unit (ICU). The model uses only two
patient specific parameters, for glucose clearance and insulin
sensitivity. The optimization of these parameters is
accomplished through a novel integration-based fitting
approach, and a piecewise linearization of the parameters. This
approach reduces the non-linear, non-convex optimization
problem to a simple linear equation system. The method was
tested on long-term blood glucose recordings from 17 ICU-patients,
resulting in an average error of 7%, which is in the
range of the sensor error. One-hour predictions of blood
glucose data proved acceptable with an error range between 7-
11%. These results verify the model’s ability to capture longterm
observed glucose-insulin dynamics in hyperglycaemic
ICU patients