research

Full-scale fire tests of post-tensioned timber beams

Abstract

This paper describes a series of full-scale furnace tests on loaded post tensioned LVL beams. Each beam was designed to exhibit a specific failure mechanism when exposed to the standard ISO834 fire. In addition to the beams a number of steel anchorage protection schemes were also investigated. These included wrapping the ends in kaowool, using intumescent paint, covering the anchorage with fire rated plasterboard and covering the anchorage with timber (LVL). The results of the full-scale tests cover temperature distributions through the timber members during the tests, the temperatures reached within the cavity and those of the tendons suspended within the cavity, the relaxation of the tendons during the test, the failure mechanisms experienced, and a summary of the anchorage protection details and their effectiveness. Recommendations for the design of both post-tensioned timber beams and associated anchorages are also provided

    Similar works