Assessment of Fences as Noise Barriers: A Case Study in New Cairo, Egypt

Abstract

Noise levels in Egypt exceed acceptable thresholds due to high population and lack of mandatory sound regulations. According to noise measurements done by “The National Network for Noise Level Measurement in Greater Cairo” most of the areas examined ( main squares, industrial areas, main roads, residential areas, commercial and administrative areas in Cairo governorate)  had shown that noise levels exceeded the standard permissible levels that are identified by the Environmental Law 4/1994 and its executive regulations. Noise levels reached up to 75-85 decibels (dB), which is considered unacceptable as noise levels should not exceed 65 dB during daytime and 55 dB during night due to law number 4/1994. On the other hand, fences are considered a common feature within the Egyptian urban context and are mainly constructed for safety and privacy reasons. This research assesses the effectiveness of existing fences as noise barriers and specifies factors that reduce noise levels. Site measurements and photographs were taken for the fence of a residential compound in new Cairo, where noises arising from surrounding places cause annoyance. MEP services were the main sources of disturbing continuous noise along with social activities and traffic noises. Measurements were performed using TM-102 digital sound level meter. Readings were recorded at various time intervals in front and behind of the fence and noise reduction levels were calculated. Measurements revealed that the fence acts as a good noise barrier and that combined configuration of the fence resulted in the attenuation of noise to acceptable levels

    Similar works