CORE
CO
nnecting
RE
positories
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Research partnership
About
About
About us
Our mission
Team
Blog
FAQs
Contact us
Community governance
Governance
Advisory Board
Board of supporters
Research network
Innovations
Our research
Labs
research
The Impact of Vein Mechanical Compliance on Arteriovenous Fistula Outcomes
Authors
Rachel Barnes
Richard Barnes
+3 more
Ian C. Chetter
Michael Fagan
George E. Smith
Publication date
25 January 2016
Publisher
'Elsevier BV'
Doi
Abstract
© 2016 Elsevier Inc. Background Arteriovenous fistulae (AVFs) are the preferred access for hemodialysis but suffer a high early failure rate. The aim of this study was to determine how venous distensibility, as measured in vitro, relates to early outcomes of AVF formed with the sampled vein. Methods Ethical approval was obtained for all aspects of this study. During AVF formation a circumferential segment of the target vein was sampled. Mechanical stress testing of the venous segments was undertaken using a dynamic mechanical analyzer, with progressive stress loading at 2 N/min to a maximum of 10 N or until sample disruption. Stress-strain curves were obtained for vein samples and Young's modulus (YM) calculated. Duplex assessment of the fistulae was undertaken at 30 days. Results Thirty patients consented to participate with 29 samples obtained for analysis. Statistical comparison of YM demonstrated no relationship with common cardiovascular risk factors or dialysis status. Subject age greater than 65 was the only patient factor which showed a significant difference in YM (P = 0.05). Furthermore, a negative correlation was confirmed between age and YM (Pearson's r = -0.465, P < 0.05). Nine of the 29 subjects suffered an early AVF failure. Mann-Whitney U testing for differences in distribution reported that YM was significantly higher in those fistulas which failed (P < 0.005). Conclusions Reduced venous compliance appears to result in higher failure rates of AVFs. With the advancement of clinical tools such as speckle tracing ultrasound identification of vessel compliance in vivo may produce valuable additional information for clinicians planning AVF surgery
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Supporting member
Repository@Hull - Worktribe
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:hull-repository.worktribe....
Last time updated on 27/02/2018
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1016%2Fj.avsg.2015...
Last time updated on 09/01/2021