Experimental Tests of the Q2 Drift Tubes Prototype Chamber for the CMS Muon Barrel

Abstract

The performances of cells with stainless steel wire and gold-plated tungsten wire are compared in terms of collected charge and time resolution. The multiplication factor has been measured with cosmic rays and a radioactive source