research

Argon spill in the hall of the ATLAS experiment

Abstract

A hazard analysis is in progress to determine the operation mode of the ventilation system in the ATLAS hall in case of an Argon spill. Two risk scenarios have been investigated so far. In the first, the behaviour of an Argon gas pool is calculated for different ventilation strategies. In the second, the behaviour of Argon gas leaking from the bottom part of the detector is studied for different flows. The description of the study, results and conclusions are presented

    Similar works