We consider the use of {\Delta}{\Sigma} modulators in ac motor drives,
focusing on the many additional degrees of freedom that this option offers over
Pulse Width Modulation (PWM). Following some recent results, we show that it is
possible to fully adapt the {\Delta}{\Sigma} modulator Noise Transfer Function
(NTF) to the rest of the drive chain and that the approach can be pushed even
to a fine adaptation of the NTF to the specific motor loading condition. We
investigate whether and to what extent the adaptation should be pursued. Using
a representative test case and extensive simulation, we conclude that a mild
adaptation can be beneficial, leading to Signal to Noise Ratio (SNR)
improvements in the order a few dB, while the advantage pushing the adaptation
to the load tracking is likely to be minimal.Comment: Sample code available at http://pydsm.googlecode.co