CORE
CO
nnecting
RE
positories
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Research partnership
About
About
About us
Our mission
Team
Blog
FAQs
Contact us
Community governance
Governance
Advisory Board
Board of supporters
Research network
Innovations
Our research
Labs
Effect of ultrasonic activation on dentinalr tubule penetration of Bio-C temp and ultracal XS: A comparative CLSM assessment
Authors
Delia Bustamante
Carolina Cáceres
+4 more
María Consuelo Magasich
Sven Eric Niklander
Fernando Peña-Bengoa
Catalina Wastavino
Publication date
1 January 2023
Publisher
Kare Publishing
Doi
Abstract
Indexación: Scopus.Objective: The aim of this study was to compare the effect of ultrasonic activation (UA) on tubular penetration between Bio-C Temp and Ultracal XS intracanal medicaments. Methods: Forty single-rooted human premolars were endodontically prepared and divided into 4 experimental groups (n=10): Bio-C Temp, Bio-C Temp+UA, UltraCal XS and UltraCal XS+UA. All medicaments were previously mixed with a specific calcium marker (Fluo-3) and passively injected into the canals. The samples were incubated for 7 days. For each tooth, 1 mm thick sections were obtained from the middle and apical thirds of the canals. The samples were examined by confocal laser scanning microscopy (CLSM) and the depth and area of penetration were determined for each group. The Student t test was used to compare results between groups (p<0.05). Results: UA increased the depth and penetration area of Bio-C Temp and Ultracal XS, showing significant differences in the penetration area of the apical third for Bio-C Temp (p<0.0339). Bio-C Temp presented greater tubular penetration than Ultracal XS, showing significant differences in the depth of penetration in the apical third (p<0.0005), and in the penetration area in the middle (p<0.0016) and apical third (p<0.0339) after UA. Conclusion: UA increases tubular penetration (both depth and area) of Bio-C Temp at the apical third but has no significant effect on Ultracal XS. Bio-C Temp has a greater depth and tubular penetration area than Ultracal XS after UA. © 2023 Kare Publishing. All rights reserved.https://jag.journalagent.com/eurendodj/pdfs/EEJ-24196-ORIGINAL_ARTICLES-PE%D1A-BENGOA.pdfhttps://eurendodj.com/jvi.aspx?un=EEJ-24196&volume=8&issue=
Similar works
Full text
Available Versions
Repositorio Institucional Académico (RIA) de la Universidad Andrés Bello
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:repositorio.unab.cl:ria/57...
Last time updated on 05/02/2025