Muscle Contracture Emulating System for Studying Artificially Induced Pathological Gait in Intact Individuals

Abstract

When studying pathological gait it is important to correctly identify primary gait anomalies originating from damage to the central nervous and musculoskeletal system and separate them from compensatory changes of gait pattern, which is often challenging due to the lack of knowledge related to biomechanics of pathological gait. A mechanical system consisting of specially designed trousers, special shoe arrangement, and elastic ropes attached to selected locations on the trousers and shoes is proposed to allow emulation of muscle contractures of soleus (SOL) and gastrocnemius (GAS) muscles and both SOL-GAS. The main objective of this study was to evaluate and compare gait variability as recorded in normal gait and when being constrained with the proposed system. Six neurologically and orthopedically intact volunteers walked along a 7-m walkway while gait kinematics and kinetics were recorded using VICON motion analysis system and two AMTI forceplates. Statistical analysis of coeffi cient of variation of kinematics and kinetics as recorded in normal walking and during the most constrained SOL-GAS condition showed comparable gait variability

    Similar works

    Full text

    thumbnail-image

    Available Versions