CORE
CO
nnecting
RE
positories
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Research partnership
About
About
About us
Our mission
Team
Blog
FAQs
Contact us
Community governance
Governance
Advisory Board
Board of supporters
Research network
Innovations
Our research
Labs
research
Modeling and experimental validation of a solar-assisted direct expansion air conditioning system
Authors
QP Ha
M Skibniewski
V Vakiloroaya
Publication date
3 September 2013
Publisher
'Elsevier BV'
Doi
Abstract
Continuous increase in global electricity consumption, environmental hazards of pollution and depletion of fossil fuel resources have brought about a paradigm shift in the development of eco-friendly and energy-efficient technologies. This paper reports on an experimental study to investigate the inherent operational characteristics of a new direct-expansion air conditioning system combined with a vacuum solar collector. Mathematical models of the system components are firstly derived and then validated against experimental results. To investigate the potential of energy savings, the hybrid solar-assisted air-conditioner is installed and extensively equipped with a number of sensors and instrumentation devices, for experimentation and data collection. The influence on the system energy usage of the average water temperature, storage tank size and room set-point temperature are then analyzed. Once the air-conditioned room has achieved its desired temperature, the compressor turns off while the cooling process still continues until the refrigerant pressure no longer maintains the desired temperature. The advantages of the proposed hybrid system rest with the fact that the compressor can remain off in a longer period by heat impartation into the refrigerant via the water storage tank. Results show an average monthly energy saving of about between 25% and 42%. © 2013 Elsevier B.V. All rights reserved
Similar works
Full text
Available Versions
OPUS - University of Technology Sydney
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:opus.lib.uts.edu.au:10453/...
Last time updated on 13/02/2017
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1016%2Fj.enbuild.2...
Last time updated on 05/01/2021