Dynamic subcriticality measurements using the CF neutron noise method: Videotape

Abstract

The capability to measure the subcriticality for a multiplying system with k-effective values as low as 0.3 was demonstrated for measurement times of approximately 10 s; the measured k-effective values obtained do not depend on the speed with which the solution height is changed or on whether the tank is filling or draining. As in previous experiments, the low-frequency ratios of spectral densities are all that are needed to obtain the k-effective value. This method's effectiveness for systems where conditions are changing with time as demonstrated, probably exceeds the dynamic requirements for most nuclear fuel plant processing applications. The calculated k-effective values using the KENO code and Hansen-Roach cross-sections compare well with the experimental values. Before the dynamic capability of the method can be considered fully explored, additional dynamic experiments are required for other geometries and fuel concentrations