Sneak Analysis was adapted for use in identifying human errors of commission. Flow diagrams were developed to guide the analyst through a series of questions aimed at locating sneak paths, sneak indications, sneak labels, and sneak timing. An illustration of the application of this methodology in a nuclear environment is given and a computerized tool to support Sneak Analysis is described. A nuclear power plant loss of coolant accident is used as the example of sneak analysis of reactor safety. 8 figs