'Institute of Electrical and Electronics Engineers (IEEE)'
Doi
Abstract
This paper proposes a loss-minimizing controller for synchronous reluctance motor drives. The proposed method takes core losses and magnetic saturation effects into account. The core-loss model consists of hysteresis losses and eddy-current losses. Magnetic saturation is modeled using two-dimensional power functions considering cross coupling between the d- and q-axes. The efficiency optimal d-axis current is calculated offline using the loss model and motor parameters. Instead of generating a look-up table, an approximate function was fitted to the loss-minimizing results. The loss-minimizing method is applied in a motion-sensorless drive and the results are validated by measurements.Peer reviewe