Development of scalable finite element models based on knee laxity tests on cadavers

Abstract

Aim of the study: The aim of the project was to use the results of laxity tests on cadaver knees to create scalable, subject-specific finite element (FE) models. The models were used to improve the surface geometry of unicondylar knee prostheses using optimization techniques. Material and methods: For the experimental tests, the alignment of the knee and the robot was defined by inserting carbon rods through the bones, recording CT data and then designing bone- and subject-specific 3D prints. As the FE-models rely on MRI images while the experiments use CT coordinate systems, there are differences in their positions. Therefore, a transformation matrix was used to correct the offset of the FE-model. With MeshLab the bones were aligned and then the position offsets calculated. The FE-model was built based on segmented MRI data using Mimics (Materialise NV) with the FE-program Ansys® Academic Research Mechanical (ANSYS Inc.). A multilinear elastic material model was selected as the material model for the ligaments with a uniaxial tensile test of a lateral collateral ligament as input. An initial area and length were assigned to calculate a stress-strain curve. In addition, a strain offset parameter was introduced to handle different strains. An additional internal/external stiffness was added. An important feature of the FE-model was to assign an initial strain to the ligaments. This maintains the actual geometry segmented from the MRI and helps to keep the ligament in tension. The level of detail chosen for the model also meant that there was only one principal ligament per laxity test. Results: This scalable parameter model of knee ligaments build was applied to six knees that had a native geometry and three different unicompartmental knee joint replacement geometries. The difference in position between the experiments and the FE-model could be offset. With knowledge of the transformation matrix, the FE-model could include the same implant position as implanted by the surgeon. Discussion: A reliable framework for the development of knee FE-models based on cadaver laxity testing was demonstrated. An improvement for future FE-models would be to provide fixation so that the MRI and CT scans are taken at the same position or by using fixed bone markers in both scans. Finally, initial stretching could be fixed to a certain strain value; however, the challenge is whether this solution remains scalable

    Similar works