The conditions and parameters of chromatography were selected for the quantitative determination of propionic acid and its salts in bakery products using high-performance liquid chromatography. Validation studies of the developed measurement technique confirmed its suitability for determining the content of propionic acid and its salts in bakery products in the range from 200 to 3000 mg/kg. It was shown that in 25% of the samples of smallpiece bakery products, lamb products and donuts we examined, an excess of the maximum permissible level of propionic acid and its salts was found