Abstract
The advanced oxidation process with Fenton’s reagent can be used in industrial wastewater
treatment, especially for the degradation of not easily biodegradable contaminations. Chemical oxidation
of industrial wastewater or other substances as a pre-treatment before biological purification is
the most effective method of wastewater treatment. However the Fenton process requires low pH of
wastewater and final neutralization with a big amount of iron-containing precipitate. Thes paper presents
laboratory experiments dealing with the treatment of adhesive wastewater in an sequencing
batch reactor following the Fenton process without final neutralization