research

Influence of Bolus Consistency and Position on Esophageal High-Resolution Manometry Findings

Abstract

Background Conventional esophageal manometry evaluating liquid swallows in the recumbent position measures pressure changes at a limited number of sites and does not assess motility during solid swallows in the physiologic upright position. Aim To evaluate esophageal motility abnormalities during water and bread swallows in the upright and recumbent positions using high-resolution manometry (HRM). Methods Thirty-two-channel HRM testing was performed using water (10ml each) and bread swallows in the upright and recumbent positions. The swallows were considered normal if the distal peristaltic segment >30mmHg was >5cm, ineffective if the 30-mmHg pressure band was 8cm/s. Abnormal esophageal manometry was defined as the presence of β‰₯30% ineffective and/or β‰₯20% simultaneous contractions. Results The data from 96 patients (48 F; mean age 51years, range 17-79) evaluated for dysphagia (56%), chest pain (22%), and gastroesophageal reflux disease (GERD) symptoms (22%) were reviewed. During recumbent water swallows, patients with dysphagia, chest pain, and GERD had a similar prevalence of motility abnormalities. During upright bread swallows, motility abnormalities were more frequent (p=0.01) in patients with chest pain (71%) and GERD (67%) compared to patients with dysphagia (37%). Conclusions Evaluating bread swallows in the upright position reveals differences in motility abnormalities overlooked by liquid swallows alon

    Similar works