Size-related vaporisation and ionisation of laser-induced glass particles in the inductively coupled plasma

Abstract

Ongoing discussions about the origin of elemental fractionation occurring during LA-ICP-MS analysis show that this problem is still far from being well understood. It is becoming accepted that all three possible sources (ablation, transport, excitation) contribute to elemental fractionation. However, experimental data about the vaporisation size limit of different particles in the ICP, as produced in laser ablation, have not been available until now. This information should allow one to determine the signal contributing mass within the ICP and would further clarify demands on suitable laser ablation systems and gas atmospheres in terms of their particle size distribution. The results presented here show a vaporisation size limit of laser induced particles, which was found at particle sizes between 90nm and 150nm using an Elan6000 ICP-MS. Due to the fact that the ICP-MS response was used as evaluation parameter, vaporisation and ionisation limits are not distinguishable. The upper limit was determined by successively removing the larger particles from the aerosol, which was created by ablation of a NIST610 glass standard at a wavelength of 266nm, using a recently developed particle separation device. Various particle fractions were separated from the aerosol entering the ICP. The decrease in signal intensity is not proportional to the decrease in volume, indicating that particles above 150nm in diameter are not completely ionised in the ICP. Due to the limited removal range of the particle separation device, which cannot remove particles smaller than 150nm, single hole ablations were used to determine the lower vaporisation limit. This is based on measurements showing that larger particles occur dominantly during the first 100laser pulses only. After this period, the ratio of ICP-MS counts and total particle volume was found to be constant while most of the particles are smaller than 90nm, indicating complete vaporisation and ionisation of these particles. To describe the influence of different plasma forward powers on the vaporisation limit, the range 1000-1600W was studied. Results indicate that optimum vaporisation and ionisation occurs at 1300W. However, an increase of the particle ionisation limit towards larger particles was not observed within the accuracy of this study using the full range of parameters available for optimisation on commonly used ICP-MS instrument

    Similar works