Portable neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IREN

Abstract

Accelerator-driven system (ADS) facilities world-wide opens new opportunities for nuclear physics investigations, so that a high flux of neutrons through spallation reactions can be produced at these facilities. It is known that the measurement, continuous monitoring and optimization of the particle accelerator beam intensity are among the most important actions in the operation of such facilities. Considering this point of view, this paper presents a neutron/gamma counter based on a micropixel avalanche photodiode (MAPD) and a plastic scintillator that monitors the status of the accelerator-driven intense resonance neutron source (IREN) facility by measuring the neutron-gamma intensity in the target hall. The electronics of the modular neutron counter has been designed and developed, including a bias voltage source (up to 130 V), a preamplifier (36 gain) and discriminator (>10 mV) circuit. The last product of MAPD (operation voltage- 55 V, PDE- 33 %, total number of pixels- 136900) was used as a photon readout from a plastic scintillator. The sensitive area of MAPD was 3.7*3.7 mm2 and the size of the plastic scintillator 3.7*3.7*30 mm3. The measurement was carried out in the IREN target hall, where it was necessary to monitor not only high neutron fluxes, but also gamma quanta. The experimental results demonstrated a dependence between the count rate of the detector and the frequency of the accelerator, which ranges from 2 to 50 Hz.Comment: 8 pages, 7 figure

    Similar works

    Full text

    thumbnail-image

    Available Versions