Corrosión del acero inoxidable 304 como refuerzo en concreto expuesto a cloruros y sulfatos.

Abstract

It�s evaluated the corrosion of 304 stainless steel and steel 1018, embedded in elaborated specimens of concrete on the basis of norms ASTM C470-87 and C192-81. Were elaborated concrete of ration a/c, 0,45 and 0.65 . The specimens were exposed 66 weeks in two aggressive means, solutions to 3,5% of NaCl and 3,5% of Na2SO4. The evaluation was made by the technique of Resistance to the Polarization (Rp), measurement of the corrosion potential (Ecorr) in agreement norm ASTM C-876-91. The results far beyond demonstrate a resistance to the corrosion of steel 304 in both means the one steel 1018.Se evaluó la corrosión del acero inoxidable 304 y el acero 1018, embebidos en especimenes de concreto elaborados en base a las normas ASTM C470-87 y C192-81. Se elaboraron concretos de relación a/c, 0.45 y 0.65. Los especimenes estuvieron expuestos 66 semanas en dos medios agresivos, soluciones al 3.5 % de NaCl y 3.5% de Na2SO4. La evaluación fue mediante la técnica de Resistencia a la Polarización (Rp), medición del potencial de corrosión (Ecorr), norma ASTM C-876-91. Los resultados demuestran una resistencia a la corrosión del acero 304 en ambos medios muy superior a la del acero 1018