It�s evaluated the corrosion of 304 stainless steel and steel 1018, embedded in
elaborated specimens of concrete on the basis of norms ASTM C470-87 and
C192-81. Were elaborated concrete of ration a/c, 0,45 and 0.65 . The specimens
were exposed 66 weeks in two aggressive means, solutions to 3,5% of NaCl and
3,5% of Na2SO4. The evaluation was made by the technique of Resistance to the
Polarization (Rp), measurement of the corrosion potential (Ecorr) in agreement
norm ASTM C-876-91. The results far beyond demonstrate a resistance to the
corrosion of steel 304 in both means the one steel 1018.Se evaluó la corrosión del acero inoxidable 304 y el acero 1018, embebidos en
especimenes de concreto elaborados en base a las normas ASTM C470-87 y
C192-81. Se elaboraron concretos de relación a/c, 0.45 y 0.65. Los especimenes
estuvieron expuestos 66 semanas en dos medios agresivos, soluciones al 3.5 %
de NaCl y 3.5% de Na2SO4. La evaluación fue mediante la técnica de
Resistencia a la Polarización (Rp), medición del potencial de corrosión (Ecorr),
norma ASTM C-876-91. Los resultados demuestran una resistencia a la
corrosión del acero 304 en ambos medios muy superior a la del acero 1018