CORE
🇺🇦
make metadata, not war
Services
Research
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Heat acclimation does not modify autonomic responses to core cooling and the skin thermal comfort zone
Authors
A. Sotiridis Ciuha, U. Debevec, T. Mekjavic, I.B.
Publication date
1 January 2020
Publisher
Abstract
Exercise heat acclimation (HA) is known to magnify the sweating response by virtue of a lower threshold as well as increased gain and maximal capacity of sweating. However, HA has been shown to potentiate the shivering response in a cold-air environment. We investigated whether HA would alter heat loss and heat production responses during water immersion. Twelve healthy male participants underwent a 10-day HA protocol comprising daily 90-min controlled-hyperthermia (target rectal temperature, Tre 38.5 °C) exercise sessions. Preceding and following HA, the participants performed a maximal exercise test in thermoneutral conditions (ambient temperature 23 °C, relative humidity 50%) and were, following exercise, immersed in 28 °C water for 60 min. Thermal comfort zone (TCZ) was also assessed with participants regulating the temperature of a water-perfused suit during heating and cooling. Baseline pre-immersion Tre was similar pre- and post-HA (pre: 38.33 ± 0.33 °C vs post: 38.12 ± 0.36 °C, p = 0.092). The Tre cooling rate was identical pre-to post-HA (−0.03 ± 0.01 °C·min−1, p = 0.31), as was the vasomotor response reflected in the forearm-fingertip temperature difference. Shivering thresholds (p = 0.43) and gains (p = 0.61) were not affected by HA. TCZ was established at similar temperatures, with the magnitude in regulated water temperature being 7.6 (16.3) °C pre-HA and 5.1 (24.7) °C post-HA (p = 0.65). The present findings suggest that heat production and heat loss responses during whole body cooling as well as the skin thermal comfort zone remained unaltered by a controlled-hyperthermia HA protocol. © 2020 Elsevier Lt
Similar works
Full text
Available Versions
Pergamos : Unified Institutional Repository / Digital Library Platform of the National and Kapodistrian University of Athens
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:lib.uoa.gr:uoadl:3009238
Last time updated on 10/02/2023