CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
High flow oxygen therapy at two initial flow settings versus conventional oxygen therapy in cardiac surgery patients with postextubation hypoxemia: A single-center, unblinded, randomized, controlled trial
Authors
S. Theologou Ischaki, E. Zakynthinos, S.G. Charitos, C. Michopanou, N. Patsatzis, S. Mentzelopoulos, S.D.
Publication date
1 January 2021
Publisher
Abstract
In cardiac surgery patients with pre-extubation PaO2 /inspired oxygen fraction (FiO2 ) < 200 mmHg, the possible benefits and optimal level of high-flow nasal cannula (HFNC) support are still unclear; therefore, we compared HFNC support with an initial gas flow of 60 or 40 L/min and conventional oxygen therapy. Ninety nine patients were randomly allocated (respective ratio: 1:1:1) to I = intervention group 1 (HFNC initial flow = 60 L/min, FiO2 = 0.6), intervention group 2 (HFNC initial flow = 40 L/min, FiO2 = 0.6), or control group (Venturi mask, FiO2 = 0.6). The primary outcome was occurrence of treatment failure. The baseline characteristics were similar. The hazard for treatment failure was lower in intervention group 1 vs. control (hazard ratio (HR): 0.11, 95% CI: 0.03–0.34) and intervention group 2 vs. control (HR: 0.30, 95% CI: 0.12–0.77). During follow-up, the probability of peripheral oxygen saturation (SpO2 ) > 92% and respiratory rate within 12–20 breaths/min was 2.4–3.9 times higher in intervention group 1 vs. the other 2 groups. There was no difference in PaO2 /FiO2, patient comfort, intensive care unit or hospital stay, or clinical course complications or adverse events. In hypoxemic cardiac surgery patients, postextubation HFNC with an initial gas flow of 60 or 40 L/min resulted in less frequent treatment failure vs. conventional therapy. The results in terms of SpO2 /respiratory rate targets favored an initial HFNC flow of 60 L/min. © 2021 by the authors. Licensee MDPI, Basel, Switzerland
Similar works
Full text
Available Versions
Pergamos : Unified Institutional Repository / Digital Library Platform of the National and Kapodistrian University of Athens
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:lib.uoa.gr:uoadl:3102412
Last time updated on 10/02/2023