CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Simultaneous quantification of 17α-OH progesterone, 11-deoxycortisol, Δ4-androstenedione, cortisol and cortisone in newborn blood spots using liquid chromatography-tandem mass spectrometry
Authors
P. Magnisali Chalioti, M.-B. Livadara, T. Mataragas, M. Paliatsiou, S. Malamitsi-Puchner, A. Moutsatsou, P.
Publication date
1 January 2011
Publisher
Abstract
Adrenal steroid profiling, including 17α-OH progesterone (17OHP), 11-deoxycortisol (S), Δ4-androstenedione (Δ4-A) and cortisol (F) in blood spots by tandem mass spectrometry, is used for newborn screening to detect congenital adrenal hyperplasia (CAH). Pre-analytical sample processing is critical for assay specificity and accuracy; however, it is laborious and time-consuming. This study describes the development and validation of a new Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method for the simultaneous quantification of five steroids: 17OHP, S, Δ4-A, F and cortisone (E) in blood spots from newborns. Whole blood was eluted from a 5.00. mm dried blood spot by an aqueous solution containing the deuterium-labeled internal standards d8-17OHP and d4-cortisol. The steroids extracted from blood spot into aqueous solution were subsequently purified via Extelut mini NT1 column using diethylether. The extracts were evaporated and quantified using LC-MS/MS. The detection limit was 0.25. ng/mL for 17OHP and S, 0.4. ng/mL for Δ4-A and 0.5. ng/mL for F and E. The limit of quantification was 0.5. ng/mL for 17OHP, S and Δ4-A and 1. ng/mL for F and E. Precision for 17OHP, S, Δ4-A at concentrations of 0.5, 2, and 8. ng/mL (n= 5) in fortified steroid free serum samples was 1.3-3.5% (intra-assay CV) and 7-14.8% (inter-assay CV). Precision for F and E at concentrations of 5 and 20. ng/mL was 1.5-4.8% (intra-assay, CV%) and 6-15% (inter-assay, CV%). Accuracy was calculated at concentrations of 0.5, 2, and 8. ng/mL for 17OHP, S and Δ4-A and ranged from -0.3 to 0.2%, while for F and E it ranged from -3.2 to 0.2%. Relative recoveries at concentration 2. ng/mL and 8. ng/mL for 17OHP, S, Δ4-A and at 5. ng/mL and 20. ng/mL for F and E ranged from 55% to 80%. Reference intervals were estimated for all steroids in newborns (on day 3). The steroid profile assay herein described is sensitive, specific and accurate and involves a simple pre-analytical sample manipulation; it is therefore suitable for routine analysis and provides data for samples within normal range as well as those with elevated levels. For the first time to our knowledge, cortisone levels are reported in dried blood spots from newborns. © 2011 Elsevier B.V
Similar works
Full text
Available Versions
Pergamos : Unified Institutional Repository / Digital Library Platform of the National and Kapodistrian University of Athens
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:lib.uoa.gr:uoadl:3067264
Last time updated on 10/02/2023