CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Differential effect of biventricular and right ventricular DDD pacing on coronary flow reserve in patients with ischemic cardiomyopathy
Authors
S. Deftereos Giannopoulos, G. Kossyvakis, C. Raisakis, K. Kaoukis, A. Driva, M. Panagopoulou, V. Ntzouvara, O. Theodorakis, A. Toutouzas, K. Pyrgakis, V. Stefanadis, C.
Publication date
1 January 2010
Publisher
Abstract
CRT and Coronary Flow Reserve. Background: Cardiac resynchronization therapy (CRT) has become a mainstay in heart failure management. There are also indications that upgrading of existing pacemakers to CRT systems may be of benefit. The aim of this study was to assess the effect of biventricular (BiV), compared with right ventricular (RV), pacing, on coronary flow reserve (CFR), in patients with ischemic cardiomyopathy. Methods and Results: From our database of heart failure patients implanted with BiV pacemakers, 20 patients (10 responders and 10 non-responders to CRT) were randomly selected. Left anterior descending artery coronary flow reserve was measured invasively, under BiV and RV pacing, using intracoronary adenosine to induce hyperemia. In all the 20 patients, there was a significant difference in the pairwise comparison between CFR recorded during BiV and RV pacing (mean difference 0.15, 95% confidence interval 0.07-0.23, P = 0.001). When comparing responders to non-responders, there was a significant difference as to the effect of BiV, compared with RV, pacing on CFR: mean difference (BiV minus RV CFR) was 0.26 ± 0.06 (95% confidence interval 0.13-0.39; P = 0.002), while in non-responders the difference was 0.04 ± 0.03 (95% confidence interval -0.02 to 0.10; P = 0.168). Conclusion: BiV pacing is overall associated to higher CFR, compared with RV DDD pacing. This difference is almost exclusively attributable to the beneficial effect of CRT on coronary flow reserve in CRT-responders. This effect may contribute to the beneficial action of resynchronization in the failing heart and can be viewed in the context of reports of the usefulness of upgrading RV pacemakers to CRT systems. © 2010 Wiley Periodicals, Inc
Similar works
Full text
Available Versions
Pergamos : Unified Institutional Repository / Digital Library Platform of the National and Kapodistrian University of Athens
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:lib.uoa.gr:uoadl:3130163
Last time updated on 10/02/2023