Ultrahigh evaporative heat transfer measured locally in submicron water films

Abstract

Abstract Thin film evaporation is a widely-used thermal management solution for micro/nano-devices with high energy densities. Local measurements of the evaporation rate at a liquid-vapor interface, however, are limited. We present a continuous profile of the evaporation heat transfer coefficient ( hevaph_{\text {evap}} h evap ) in the submicron thin film region of a water meniscus obtained through local measurements interpreted by a machine learned surrogate of the physical system. Frequency domain thermoreflectance (FDTR), a non-contact laser-based method with micrometer lateral resolution, is used to induce and measure the meniscus evaporation. A neural network is then trained using finite element simulations to extract the hevaph_{\text {evap}} h evap profile from the FDTR data. For a substrate superheat of 20 K, the maximum hevaph_{\text {evap}} h evap is 1.00.3+0.51.0_{-0.3}^{+0.5} 1 . 0 - 0.3 + 0.5  MW/ m2\text {m}^2 m 2 -K at a film thickness of 153+2915_{-3}^{+29} 15 - 3 + 29  nm. This ultrahigh hevaph_{\text {evap}} h evap value is two orders of magnitude larger than the heat transfer coefficient for single-phase forced convection or evaporation from a bulk liquid. Under the assumption of constant wall temperature, our profiles of hevaph_{\text {evap}} h evap and meniscus thickness suggest that 62% of the heat transfer comes from the region lying 0.1–1 μm from the meniscus edge, whereas just 29% comes from the next 100 μm

    Similar works

    Full text

    thumbnail-image